| 1. Heated extractive emissions analyzer | Continuous monitoring of combustion flue gas and industrial stack emissions | Common targets include CO, CO₂, NO, NO₂, SO₂, HCl, and HF, subject to the configured method | Use a heated probe, sample line, and gas cell when needed to prevent condensation and loss of water-soluble components | Maintain the sample path above the sample’s dew point; account for water-vapor spectral interference and dust loading | Check the required reporting range, applicable monitoring method, response time, and compatibility with the site’s sampling system |
| 2. Process-gas analyzer | Process control and troubleshooting in chemical, refining, and manufacturing operations | May include CO, CO₂, CH₄, NH₃, H₂O, and selected process-specific gases | Choose a probe, filter, and cell arrangement compatible with the process pressure, temperature, and gas composition | Define pressure and flow conditions; protect the cell from particulates, condensation, and incompatible materials | Confirm target-gas calibration, expected background gases, measurement range, and integration needs with the control system |
| 3. Combustion and burner-tuning analyzer | Combustion optimization, furnace checks, and burner performance assessment | Common measurements include CO, CO₂, NO, NO₂, and H₂O; O₂ may require a separate or additional measurement method | Use a sampling arrangement suitable for hot, particle-bearing exhaust; conditioning depends on whether wet or dry measurements are required | Keep sampling conditions consistent and avoid unplanned dilution or condensation that could alter reported concentrations | Verify whether the application needs continuous monitoring or portable diagnostic measurements, and confirm the required accuracy and response |
| 4. Biogas and landfill-gas analyzer | Digester, landfill, and renewable-gas process monitoring | Common targets include CH₄, CO₂, H₂O, and, where configured, NH₃ or H₂S | Provide particulate protection and manage moisture; select wetted materials compatible with the actual gas mixture | Consider variable moisture, pressure, and gas composition; assess corrosion and condensation risks before selecting the sample path | Check whether H₂S is within the validated measurement configuration and whether additional safety-rated equipment is required at the site |
| 5. Acid-gas monitoring configuration | Scrubber performance checks and monitoring of corrosive or acid-forming gases | Potential targets include HCl, HF, SO₂, and other gases included in the validated method | Use corrosion-resistant, suitably heated sampling components where required; minimize cold spots and reactive surfaces | Prevent condensation and adsorption losses, especially for water-soluble species; follow material-compatibility and maintenance guidance | Request evidence of performance for the specific gas matrix, concentration range, humidity, and sampling-system materials |
| 6. Low-concentration ambient or clean-gas configuration | Background-air studies, clean-process checks, and applications with low target-gas levels | Depending on the method, targets may include CO, CO₂, CH₄, N₂O, or selected volatile compounds | A long-path or otherwise sensitivity-optimized cell may be appropriate; use clean, low-background sample lines | Control leaks, contamination, pressure, and water-vapor effects; verify detection limits under the actual matrix and operating conditions | Compare validated detection limits and uncertainty with the measurement objective; do not infer trace capability from the technique alone |
| 7. Fast-response transient-gas configuration | Engine exhaust, pilot plants, and processes with rapidly changing gas composition | Possible targets include CO, CO₂, NO, NO₂, CH₄, and H₂O, depending on the configured method | Use short, low-volume sampling paths where practical; heated lines may be necessary for hot or condensable samples | System response depends on the cell volume, sample flow, line length, and spectral acquisition settings; validate the full sample train | Ask for demonstrated response time and data-update rate for the selected gases, not just the analyzer’s nominal measurement interval |